TP-27S智能差壓變送器DIFFERENTIAL PRESSURE TRANSMITTER TP-27S | | | : | ±10mmH2O~±550,000 mmH2O | | | : | LOCAL LCD WITH 4-20mA | | | : | Ex (ja) IIC T6 | | | : | ±0.1% | Physical Characteristics. Power supply : 12.35 - 30 Vdc with no load Supply voltage to permissible load relation: 0/250 Ohm for 17.35 Vdc 0/582.5 Ohm for 24 Vdc 0/882.5 Ohm for 30 Vdc Output signal : 4 -20mA, 2 wires, with superimposed digital communication (Vell 202-HART Protocol) Settling time : 150ms (at 27℃ ) Max. static pressure: 50bar ( 2 bar AT 0-25 mmH2O) Overpressure limits: 50bar on either side ( 2 bar AT 0-25 mmH2O) Process chambers volume: 10 ㎤ approx. Displacement: 0.3 ㎤ at span max. ENVIRONMENT AND CONDITIONS Temperature: Process fluid : -20 ~ + 100℃ Housing : -20 ~ + 80℃ Handling and storage : -20 ~ + 90℃ Relative Humidity : 0 ~ 99% R.H. LCD display reading : -10 ~ + 65℃ Performance Unless otherwise stated, performance specifications are referred at atmospheric pressure, nominal span, silicone oil filling and are given as a percent of span. Accuracy rating: it is assured within the following limits. Non linearity : resettable with 0.1% accuracy. Repeatability : = 0.10%. Hysteresis : = 0.10%. Dead band : negligible. OPERATING INFLUENCES Thermal drift: It is referred to -10 ~ + 65℃ range. Zero: ± 0.1%/10。K. Span: ± 0.1%/10。K at nominal range. Static pressure effect Zero: ± 0.5% / 10 bar. Span: ± 0.5% / 10 bar Over range effect Zero: on either side ± 1% at 50bar. Power supply effect : Negligible between 12.35 and 30 V dc. PHYSICAL SPECIFICATIONS Process wetted parts : Diaphragm in SUS 316 L / hastelloy C - process chambers and adapters forged steel UNI Fe50 / SUS 316 - drain and vent plugs SUS 316 - gaskets PTFE + Viton - bolts carbon steel / SUS 304. Housing : die cast aluminium alloy AL UNI 4514 finished with epoxy resin (RAL 5014). Filling fluid : silicon oil. Nameplate : stainless steel, fixed on housing. Bracket for 2" pipe mounting: zinc coated carbon steel Calibration Standard: at nominal range, direct action, transmitter mode. Optional: at the conditions specified with the order. Environmental protection: the transmitter is dust and sand tight and protected against sea waves effects as defined by IEC IP 66. Suitable for tropical climate operation as defined in DIN 50.015. Process connections: See table 1. Electrical connections : two cable entries on electronic housing, 1/2" NPT and cable gland PG 13.5 for 7 to 12mm diameter cable. Terminal board : 2 terminals for signal wiring up to 1.5 ㎟ (14 AWG). Connection for ground and cable shield. Mounting position : any position. Net weight : 5.1 Kg. EXPLOSION PROTECTION Classification Type: intrinsic safety Ex ia IIC, T6, T5, T4 Max Amb. temp.: 40℃ for T6, 55℃ for T5, 80℃ for T4 Condition A No-load voltage: = 30 V d.c. Short circuit current: = 120 mA. Max transferred power: 0,75 W. Condition B No-load voltage: = 25,2 V d.c. Short circuit current: = 152 mA. Max transferred power: 0,95 W. Note Explosion proof feature (Exd 〔ia〕 IIC T6) with the |