PD : Converter
(PULSE divider -> PULSE
Converter
The Model P/D converts pulse rate typically from meters into convenient engineering units on a totalizer.
MODEL & SUFFIX CODE
P/D-(model)(in)(out1)(out2)(out3)-(power)
-(model)
4 : 1 Output without Display
9 : 2 Outputs without Display
(input)
A : Open Collector
B : Dry Contact
C : Voltage Pulse
D : Current Pulse
R : Other Special Spec.
(output1)(output2)(output3)
A : Open Collector
B : Dry Contact
C : Voltage Pulse (Only Output 1)
D : Current Pulse (Only Output 1)
R : Other Special Spec.
N : Not Used
-(power)
W : AC 200~230V for 60 Hz
X : AC 100~120V for 60 Hz
Y : DC 18~30V
Z : Other Special Spec.
The Model P/D converts pulse rate typically from meters into convenient engineering units on a totalizer.
- Included Pulse Divider
ORDERING INFORMATION
Specify code number and variables.
- Code no. : P/D-Model/Input/Output1/Output2/Output3-Power
(Ex : P/D-4C4NN-X)
- Special Input Range (Ex : 12V Voltage Pulse)
- Specify Special Output 3 Type (Ex : 1:1 Pulse)
GENERAL SPECIFICATIONS
- Housing Material : Plastic ABS(Resin) Black
- Isolation : Input to Output to Power
INSTALLATION
- Power Supply : AC 100~120V or 200~230V / 60Hz (about 3VA), DC 18~30V (about 3Watts)
- Operating Temperature : -5 ~ +55 C
- Operating Humidity : 90% RH max. (Non-condensing)
- Mounting : Wall or Rail mounting
- Dimension : 52(W) X 77(H) X 112(D) (Unit : mm)
- Weight : about 400g
PERFORMANCE
- Temperature Coefficient : 0.015% / C
- Insulation Resistance : 100 MW or more with 500V DC between Input / Output / Power
- Dielectric Strength : 1500V AC 0.5 mA/Min (Input to Output to Power)
- Changeable Range : 0.00001 ~ 0.99999
SCHEMATIC CIRCUIT & CONNECTION DIAGRAM